Technology Magazine Products About HORECA Contact us

Engineering · AF Natural Spring

AGUAFLUX Technology

The flagship multistage filtration run: Natural Spring purity without interrupting the flow — and without dosing chemicals, wasting water or stripping the minerals.

Reading time 9 minLast reviewed November 2026DeepTech Limited, engineering
Spring water — the source every AGUAFLUX run is specified from

The three guarantees

Every AGUAFLUX whole-house and whole-venue system is specified around the same three commitments. They are measured, not asserted — and they are what separates an in-line filtration run from a water softener or a reverse-osmosis unit.

99.9999%Biological risks removed, without chemicals
ZeroMicro- and nano-plastics passing through or added
100%Natural minerals and electrolytes preserved

Biological water safety

Bio-contamination can lead to gastrointestinal infections, acne, chronic inflammation and long-term toxic damage — even without drinking the water, through showers, washing and food preparation.

Many parts of the developing world still struggle with biocontamination in the supply, while others sterilise with chemicals such as chlorine, replacing one problem with another. AGUAFLUX removes the biological risk without dosing anything into the water.

Water flowing through a treatment stage
Biological risks are removed in the staged run, without dosing the supply. Image: AGUAFLUX.

AGUAFLUX vs reverse osmosis

Reverse osmosis is the obvious comparison, and on the four parameters that matter operationally it loses on all four.

ParameterAGUAFLUX Natural SpringReverse osmosis
Speed and footprintFast and compact — no additional pumps, tanks or points of failure; high-purity water on demand.Slow, and needs high-pressure pumps plus large storage tanks sized to peak demand.
Water waste0% wasted. Nothing is rejected to drain.Around 70% of the feed water goes to waste — typically twice as much rejected as produced.
Minerals100% of naturally occurring magnesium, potassium, calcium and other electrolytes stay in the water.Most minerals are stripped, which lowers pH and leaves the water acidic and corrosive.
Service lifeFilters last up to 3 years, with simple maintenance and a service model that creates local jobs.Replacement cycle of 3–6 months, by design — a steady stream of cartridges and fees.

How it works

The system is built from materials science rather than a single cartridge. Water passes through a staged train — sediment, KDF and granular carbon, ion exchange, block carbon — in one direction, each stage taking on what the previous stage lets through. No pumps, no tanks, no second pass.

Spring water — the source every AGUAFLUX run is specified from
One in-line run, no pumps, no tanks, no second pass. Image: AGUAFLUX.

Because the stage order and the cartridge grade are set from a laboratory panel of the source water, two installations on the same street can legitimately be specified differently. That is the point: the water decides the specification.

Water analysis

Every AGUAFLUX system is specified from a laboratory panel of the water on site. This is what the multistage run does to each parameter — and what it deliberately leaves alone.

ParameterIn the source waterAfter AGUAFLUX
Sediment, grit, rustCarried in from the mains or the boreholeHeld back at the sediment pre-filter
Free chlorineDosed into the municipal supplyRemoved at the block-carbon stage
Taste and odourFollow the chlorine and the organicsRemoved with the carbon stage
Bacteria and cystsVary with source and season99.9999% of key biological risks held back, without chemicals
Micro- and nano-plasticsPresent in tap water and in bottled waterNone pass through, and none are added by the filters
Magnesium, potassium, calcium, sodiumThe natural mineral content of your sourcePreserved — 100% stays in the water
Hardness and limescaleAs it is in the sourceNot softened — dissolved hardness passes through
Iron and manganeseCommon in Bali borehole waterHandled by selective media when the panel calls for it
pHThe pH of the sourceUnchanged — nothing is dosed, nothing is stripped

Platform figures apply to the whole-house and whole-venue in-line run and are conditional on the source water. A before-and-after panel is run on the survey sample — that panel, not this table, sets the specification.

Pricing

Our systems are made to last, so they save more the longer they run. For a quote tailored to your site, contact our distribution partners.

Next step

Send us your source-water analysis, or the address and a description of the site. Our engineers come back with the stage order, the cartridge grade and the service interval that fit the water you actually have.

  • A technical call with the engineer who sizes the system
  • A stage-by-stage specification from your panel, not from a catalogue
  • The service interval in writing, with the cartridge rating that applies

Editorial note. This page is maintained by the technical team at DeepTech Limited, the company behind AGUAFLUX. They run the source-water surveys, design the systems, set the cartridge specifications and train the service partners who look after every installed system. A figure stays on this page only while a report names the model it applies to; where the evidence sits behind a claim, the test report travels with the proposal.

Request a consultation

A technical call with the engineer who sizes the system, a stage-by-stage specification from your panel, and the service interval in writing.

Request a proposal

Leave your details and our distributor will reply within one business day.